  • UHV-8003 ハンディ型超音波部分放電検出器

    UHV-8003ポータブル超音波部分放電検出器は、主に部分放電によって発生する超音波信号を受信し、変圧器、GIS、モーター、ケーブルおよびがいし、架空ケーブルなどから部分放電が発生する有無と場所を判断するために使用されます。主に構成されています。 by: ポータブル超音波部分放電検出器 - メインホスト、接触超音波センサー、高周波

    ハンディ型超音波部分放電検出器 UHV-8003 製品詳細



    UHV-8003 Partial Discharge Detector

    HTY_7649

    Product Introduction

    Partial discharge detector manufactures can be widely used for partial discharge detection in power systems, including insulation state detection of high-voltage and other equipment. The discharge degree of electrical equipment can be measured by the following indicators.

    This product can be widely used in partial discharge detection of power system, including high voltage switchgear, ring network cabinet, voltage / current transformer, transformer (including dry type transformer), GIS, overhead line, cable and other equipment insulation state detection, through the following indicators to measure the discharge degree of electrical equipment

    Partial discharge intensity detection: by measuring the discharge signal in one power frequency cycle, the partial discharge intensity is characterized according to the maximum value (dB) in the discharge pulse sequence

    Partial discharge frequency detection: by measuring the discharge signal in one power frequency cycle, the discharge pulse is extracted and the partial discharge frequency is characterized according to the number of discharge pulses.


    HTY_7580

    Product application

    Power generation and distribution enterprises

    Rail system

    Petrochemical power supply system

    Aerospace testing field

    Automated inspection field


    製品パラメータ

    TEV測定

    測定範囲0dB-60 dB
    解決0.1dB
    精度±1dB
    1サイクルあたりの最大パルス1400
    測定周波数帯域3~100MHz

    AE measurement

    測定範囲0dB~60dB
    解決0.1dB
    Frequency Range±1dB
    Frequency Range20~200 kHz

    AA,AA1,AA2 measurement

    測定範囲0dB~60dB
    解決0.1dB
    精度±1dB
    センサーの中心周波数40kHz

    UHF measurement

    検出頻度300-2000MHz
    測定範囲0-60 dBV
    感度<1dBm
    センサー周波数帯域300-2000MHz

    HFCT measurement

    センサー伝送インピーダンス5mV/mA
    検出頻度1~30MHz
    解決0.1dB
    感度≤50pC

    ハードウェア

    シェルABS
    Screen4.3 inch RGB LCD screen, resolution 800*480
    Sampling accuracy12bit
    Synchronization modeInternal synchronization
    コネクタUSBインターフェース(充電器入力もあり)
    3.5mm stereo headphone jack
    外部センサー入力インターフェース
    Earphone8 Ω minimum
    SD cardStandard configuration 16G ~ 64G
    内蔵バッテリー3.7V/10000mAh lithium battery
    Operating hoursApproxi. 12 hours
    充電器DC 5V/3A
    動作温度-20 ~ 50℃
    湿度20-85% relative humidity
    Volume and weight210*100*35(mm) 0.4KG(host)
    製品の特徴

    1、Configure different sensors to realize the partial discharge detection of almost all high-voltage electrical equipment;

    2、Provide a variety of discharge patterns such as time-domain waveform, PRPD, PRPS, etc., to realize the analysis of different discharge types;

    3、Humanized man-machine interface facilitates data management of different devices;

    4、Built-in ultrasonic sensor and transient ground voltage (hereinafter referredtoas TEV) sensor, which can be connected to special sensors such as transformers, GIS, overhead lines, cables, etc.;

    5、The non-invasive detection method does not require power failure during the test process, and there is no need to configure an additional high-voltage source, whichismore convenient to use than the traditional pulsed partial discharge detector factory;

    6、The test bandwidth range is 30kHz ~ 2.0GHz, which is suitable for the detectionprinciple of various frequency bands


    FAQs:

    Q:What is the UHV-8003 Handheld Ultrasonic Partial Discharge Detector? 

    A:The UHV-8003 is a portable partial discharge detection instrument designed to detect and analyze partial discharge signals from high-voltage electrical equipment. It can be used for equipment such as transformers, GIS, motors, cables, insulators, and overhead lines.

    Q:What is partial discharge (PD)? 

    A:Partial discharge is a localized electrical discharge that occurs in part of an insulation system without completely bridging the insulation between conductors. Continuous or severe partial discharge may indicate insulation defects and can contribute to insulation deterioration.

    Q:Can the UHV-8003 perform non-invasive testing? A:Yes. The product uses a non-invasive detection method and is designed to detect partial discharge without requiring an additional high-voltage test source. According to the manufacturer's product information, certain detection applications can be performed without shutting down the equipment.

    Q:How is the UHV-8003 different from a traditional offline partial discharge test system? A:A traditional offline PD test system generally requires a dedicated high-voltage test source and is often used for controlled laboratory or commissioning tests. The UHV-8003 focuses on portable, non-invasive field detection. It can receive PD-related signals without requiring an additional high-voltage source, making it particularly useful for inspection and condition assessment applications.








    あなたはおそらくそれも好きでしょう

    • 何か質問がある!

      いつでもお気軽にご連絡ください
      お問い合わせ
    • ご来店ください

      6号館、光学谷光学機械産業園区、高新5路84号、
      中国湖北省武漢市東湖新技術開発区

    • 私達に電子メールを送り

      qiao@hvtest.cc

    • お電話ください

      +86-15871365102