  • UHV-316 Motor Test Bench

    Power supply transformer no-load and load characteristics test, frequency doubling-induction test and power frequency voltage withstand test on the tested transformer

    Product Details of UHV-316 Motor Test Bench

    Product Introduction:

    The motor test bench is a custom-designed, non-standard system that complies with relevant national standards such as GB/T755-2019. It is engineered based on the principles of safety, reliability, economy, practicality, ease of operation, and scalability, incorporating advanced technology to perform complex test functions for both high- and low-voltage three-phase asynchronous motors and DC motors, tailored to Party A's specific technical requirements and motor types.


    Product Features:

    This motor test bench is designed with a focus on reliability, safety, economy, practicality, ease of operation, and maintainability, while also incorporating advanced technological features.

    The measurement and control system of the testing equipment adopts a robust architecture comprising an industrial control computer, PLC control, and digital display instruments.

    All components of the test system, including the bench, electrical control cabinets, and enclosures, feature a spray-coated surface finish. All labels and markings are clearly printed and designed for long-lasting adhesion.

    Every piece of equipment and all installation materials used in the testing system consist of new components. Furthermore, the measurement units for all parts and instruments, as well as all associated drawings and documentation, adhere to the International System of Units (SI) standard.


    Product Parameters:

    Equipment power supply

    Power supply voltage460V頻度60Hz
    Phase number3 Phase定格出力Not less than 500KVA

    Test capacity

    Serial numberMotor type定格電圧Test frequencyNo-load test述べる
    1Low voltage three-phase asynchronous motor230V-660VSine wave 50Hz, 60Hz3kW-1250kWThe high-power motor adopts low-voltage test, and the motor rotates at full speed
    2High voltage three-phase asynchronous motor3KV-13.2KVSine wave 50Hz, 60Hz50kW-8000kW
    3DC motorDC800V or less直流100kW-800kW

    The main test parameters and accuracy of the test bench

    Alternating current voltage
    Low pressure measurement10-700Vac精度±0.2%FS
    Alternating current
    Low pressure measurement1-1200A精度±0.2%FS
    High voltage measurement1-500A精度±0.2%FS
    DC measurement1-500A精度±0.2%FS
    DC resistance0.005-2000Ω精度±0.2%FS
    温度-20-200℃精度±1℃
    頻度45-65Hz精度±0.1Hz